| Compatible Models | : | GF802U-050-AS36~GF802U-075-AS36~GF802U-100-AS36~GF802U-100-AW60~GF802U-125-AS60~GF802U-150-AS60~R802TA-050-3-14-MSA~R802TA-050-3-14-MXA~R802TA-075-3-17-MSA~R802TA-075-3-17-MXA~R802TA-075-4-17-MSA~R802TA-075-4-17-MXA~R802TA-100-4-17-MSA~R802TA-100-4-17-MXA~R802TA-100-5-21-MSA~R802TA-100-5-21-MXA~R802TA-125-5-24-MSA~R802TA-125-5-24-MXA~R802TA-150-5-24-MSA~R802TA-150-5-24-MXA~R802VA-075-3-17-ZSA~R802VA-075-3-17-ZSB~R802VA-075-3-17-ZXB~R802VA-075-4-21-ZSA~R802VA-075-4-21-ZSB~R802VA-075-4-21-ZXB~R802VA-100-5-21-ZSA~R802VA-100-5-21-ZSB~R802VA-100-5-21-ZXB~R802VA-125-5-24-ZSA~R802VA-125-5-24-ZSB~R802VA-125-5-24-ZXB~RGLE-07-A-M-K~RGLE-07-B-R-Q~RGLE-10-B-R-M~RGLE-12-A-R-M~RGLK-05-A-U-E~RGLK-07-A-M-E~RGLK-07-A-M-G~RGLK-07-A-U-E~RGLK-10-A-M-E~RGLK-10-B-R-J~RGLK-12-A-R-J~RGLK-15-A-R-J~RGLR-07-A-M-K~RGLR-07-B-R-Q~RGLR-10-B-R-M~RGLR-12-A-R-M~RGPQ-05-A-U-E~RGPQ-07-A-M-E~RGPQ-07-A-M-G~RGPQ-10-A-M-E~RGPQ-10-B-R-J~RGPQ-12-A-R-J~RGPQ-15-A-R-J~S802TA-050-3-14-MSA~S802TA-050-3-14-MXA~S802TA-075-3-17-MSA~S802TA-075-3-17-MXA~S802TA-075-4-17-MSA~S802TA-075-4-17-MXA~S802TA-100-4-17-MSA~S802TA-100-4-17-MXA~S802TA-100-5-21-MSA~S802TA-100-5-21-MXA~S802TA-125-5-24-MSA~S802TA-125-5-24-MXA~S802TA-150-5-24-MSA~S802TA-150-5-24-MXA~S802VA-075-3-17-ZSA~S802VA-075-3-17-ZSB~S802VA-075-3-17-ZXB~S802VA-075-4-21-ZSA~S802VA-075-4-21-ZSB~S802VA-075-4-21-ZXB~S802VA-100-5-21-ZSA~S802VA-100-5-21-ZSB~S802VA-100-5-21-ZXB~S802VA-125-5-24-ZSA~S802VA-125-5-24-ZSB~S802VA-125-5-24-ZXB |
| Cut In Temperature | : | 145 F |
| Cut Out Temperature | : | 165 F |
| Differential Temperature | : | 20 F |
| Electrical Connection Type | : | Quick-Connect |
| For Use With | : | HVAC Equipment |
| Function Type | : | Limit Switch |
| Number of Poles | : | 1 |
| Package Quantity | : | 1 |
| Product Family | : | ProTech |
| Product Type | : | Limit Switch |
| Product Weight | : | 0.1 lbs |
| Reset Type | : | Auto |
| Switch Action | : | Limit Open on Rise |
| Switch Contact Type | : | SPST (Normally Closed) |
| Switching Current | : | 15~10 A |
| Switching Voltage | : | 120~230 V |
| UL Listed | : | No |
This ProTech limit switch is a genuine Rheem factory repair part designed to protect HVAC equipment from excessive temperatures. As an essential safety component for a wide range of furnace models, it interrupts the electrical circuit when unsafe heat levels are detected. The switch features an automatic reset function, ensuring the system can resume operation without manual intervention once conditions are safe.
- Safety Control:Functions as a critical safety device, opening the electrical circuit at 165°F to prevent overheating.
- Automatic Reset:Automatically closes the circuit once the temperature drops to 145°F, restoring normal furnace operation without manual intervention.
- Electrical Rating:Rated for 15 Amps at 120
- V and 10 Amps at 230
- V to accommodate common residential and light commercial systems.
- Simple Installation:Designed for board mounting and features quick-connect terminals for fast and straightforward replacement.
- Switch Configuration:Features a single-pole, single-throw (SPST), normally closed contact for dependable performance.